The capillary plane terminal system is a novel HVAC system which can be used in office or residential buildings with dedicated outdoor air system. The capillary mats buried in the surface grout of the ceiling or the wall or the floor handle the interior sensible space cooling load with the handled dedicated air taking on the rest latent cooling load to keep the indoor parameters to be desired state. In this paper, with an example of a typical residential room where the capillary mats are installed on the ceiling, by using the method of CFD the indoor air flows under different modes in summer and winter are simulated and the temperature, velocity, relative humidity, predicted mean vote (PMV) and predicted percent dissatisfied (PPD) fields are presented and analyzed. Based on the simulation results, the indoor thermal environments are evaluated. And the optimal air flow mode is recommended correspondingly. These will be useful to the design and application of the capillary plane HVAC terminal system.
Skip Nav Destination
ASME 2008 2nd International Conference on Energy Sustainability collocated with the Heat Transfer, Fluids Engineering, and 3rd Energy Nanotechnology Conferences
August 10–14, 2008
Jacksonville, Florida, USA
Conference Sponsors:
- Advanced Energy Systems Division and Solar Energy Division
ISBN:
978-0-7918-4320-8
PROCEEDINGS PAPER
Numerical Simulation of Indoor Air Flow in Capillary Plane HVAC Terminal System
Wei Bing,
Wei Bing
North China Electric Power University, Baoding, Hebei, China
Search for other works by this author on:
Li Li,
Li Li
North China Electric Power University, Baoding, Hebei, China
Search for other works by this author on:
Jiang Lu,
Jiang Lu
North China Electric Power University, Baoding, Hebei, China
Search for other works by this author on:
Zhang Wei
Zhang Wei
North China Electric Power University, Baoding, Hebei, China
Search for other works by this author on:
Wei Bing
North China Electric Power University, Baoding, Hebei, China
Li Li
North China Electric Power University, Baoding, Hebei, China
Jiang Lu
North China Electric Power University, Baoding, Hebei, China
Zhang Wei
North China Electric Power University, Baoding, Hebei, China
Paper No:
ES2008-54081, pp. 181-191; 11 pages
Published Online:
June 22, 2009
Citation
Bing, W, Li, L, Lu, J, & Wei, Z. "Numerical Simulation of Indoor Air Flow in Capillary Plane HVAC Terminal System." Proceedings of the ASME 2008 2nd International Conference on Energy Sustainability collocated with the Heat Transfer, Fluids Engineering, and 3rd Energy Nanotechnology Conferences. ASME 2008 2nd International Conference on Energy Sustainability, Volume 2. Jacksonville, Florida, USA. August 10–14, 2008. pp. 181-191. ASME. https://doi.org/10.1115/ES2008-54081
Download citation file:
6
Views
Related Proceedings Papers
Related Articles
Potential of Utilizing Thermal Energy Storage Integrated Ground Source Heat Pump System to Reshape Electricity Demand in the United States
J. Eng. Sustain. Bldgs. Cities (August,2021)
Airflow and Air Quality in a Large Enclosure
J. Sol. Energy Eng (May,1995)
Film Effectiveness Downstream of a Row of Compound Angle Film Holes
J. Heat Transfer (April,2005)
Related Chapters
Dynamic Cool Roofing Systems
Advanced Energy Efficient Building Envelope Systems
Numerical Simulation Research on a Fixed Bed Gasifier
International Conference on Information Technology and Management Engineering (ITME 2011)
Inside the Building
Geothermal Heat Pump and Heat Engine Systems: Theory and Practice