Combined cooling, heating, and power (CCHP) systems generate electricity at or near the place of consumption and utilize the accompanying waste heat to satisfy the building’s thermal demand. CCHP systems have often been cited as advantageous alternatives to traditional methods of power generation and one of the critical components affecting their performance is the power generation unit (PGU). This investigation examines the effect of the PGU on the energy, economical, and environmental performance of CCHP systems. Different size PGUs are simulated under the following operational strategies: follow the building’s electric load, follow the building’s thermal load, and operate at constant load. An internal combustion engine is used as the PGU in the CCHP system to meet hourly electric, cooling, heating, and hot water loads of a typical office building for a year. Annual operational cost, primary energy consumption (PEC), and carbon dioxide emissions (CDE) are found for two cities and compared to a conventional building. Finally, a simple optimization is performed to determine the best engine load for each hour during the simulation. Among the results, the smallest engine generally yielded the lowest costs and lowest PEC; but, no such trend was found with regards to CDE.
Skip Nav Destination
ASME 2009 International Mechanical Engineering Congress and Exposition
November 13–19, 2009
Lake Buena Vista, Florida, USA
Conference Sponsors:
- ASME
ISBN:
978-0-7918-4379-6
PROCEEDINGS PAPER
Effect of the Power Generation Unit Operation on the Energy, Economical, and Environmental Performance of CCHP Systems for a Small Commercial Building
Anna K. Hueffed,
Anna K. Hueffed
Mississippi State University, Mississippi State, MS
Search for other works by this author on:
Pedro J. Mago,
Pedro J. Mago
Mississippi State University, Mississippi State, MS
Search for other works by this author on:
Louay M. Chamra
Louay M. Chamra
Mississippi State University, Mississippi State, MS
Search for other works by this author on:
Anna K. Hueffed
Mississippi State University, Mississippi State, MS
Pedro J. Mago
Mississippi State University, Mississippi State, MS
Louay M. Chamra
Mississippi State University, Mississippi State, MS
Paper No:
IMECE2009-12687, pp. 507-516; 10 pages
Published Online:
July 8, 2010
Citation
Hueffed, AK, Mago, PJ, & Chamra, LM. "Effect of the Power Generation Unit Operation on the Energy, Economical, and Environmental Performance of CCHP Systems for a Small Commercial Building." Proceedings of the ASME 2009 International Mechanical Engineering Congress and Exposition. Volume 6: Emerging Technologies: Alternative Energy Systems; Energy Systems: Analysis, Thermodynamics and Sustainability. Lake Buena Vista, Florida, USA. November 13–19, 2009. pp. 507-516. ASME. https://doi.org/10.1115/IMECE2009-12687
Download citation file:
5
Views
0
Citations
Related Proceedings Papers
Related Articles
Supervisory Feed-Forward Control for Real-Time Topping Cycle CHP Operation
J. Energy Resour. Technol (March,2010)
Design of a Multigenerational System With Absorption Cooling for a Residential Community: A Case Study
J. Energy Resour. Technol (June,2021)
Screening Analysis for EPACT-Covered Commercial HVAC and Water-Heating Equipment
J. Energy Resour. Technol (June,2002)
Related Chapters
Physiology of Human Power Generation
Design of Human Powered Vehicles
Introduction
Consensus on Operating Practices for Control of Water and Steam Chemistry in Combined Cycle and Cogeneration
Dynamic Cool Roofing Systems
Advanced Energy Efficient Building Envelope Systems