The dynamic pressure transmitter based on piezoelectric dynamic pressure transducer is designed. The characteristic of dynamic pressure transmitter when pipeline leak happened is analyzed. The dynamic pressure signal is suitable for pipeline leak detection for quick-change of pipeline internal pressure, while the static pressure is suitable for slow-change of pipeline internal pressure. This paper indicated that the dynamic pressure signal could be adjust to this detection that the pressure changes quickly in the pipeline. Field tests show that the proposed method detects pipeline leak rapidly and precisely. The field test in 68.2 km pipeline shows that the least detected leakage ratio with dynamic pressure method is 0.6 percent pipeline throughput and location error is 80 m.
Skip Nav Destination
2010 8th International Pipeline Conference
September 27–October 1, 2010
Calgary, Alberta, Canada
Conference Sponsors:
- International Petroleum Technology Institute and the Pipeline Division
ISBN:
978-0-7918-4422-9
PROCEEDINGS PAPER
Research on Pipeline Leak Detection Method Based on Joint Pressure and Dynamic Pressure
Likun Wang,
Likun Wang
R&D Center of PetroChina Pipeline Company, LangFang, HeBei, China
Search for other works by this author on:
Min Xiong,
Min Xiong
R&D Center of PetroChina Pipeline Company, LangFang, HeBei, China
Search for other works by this author on:
Jinyun Zhao,
Jinyun Zhao
R&D Center of PetroChina Pipeline Company, LangFang, HeBei, China
Search for other works by this author on:
Hongchao Wang,
Hongchao Wang
R&D Center of PetroChina Pipeline Company, LangFang, HeBei, China
Search for other works by this author on:
Bin Xu,
Bin Xu
R&D Center of PetroChina Pipeline Company, LangFang, HeBei, China
Search for other works by this author on:
DongLiang Yu,
DongLiang Yu
R&D Center of PetroChina Pipeline Company, LangFang, HeBei, China
Search for other works by this author on:
Yi Sun,
Yi Sun
R&D Center of PetroChina Pipeline Company, LangFang, HeBei, China
Search for other works by this author on:
Yongjun Cai
Yongjun Cai
R&D Center of PetroChina Pipeline Company, LangFang, HeBei, China
Search for other works by this author on:
Likun Wang
R&D Center of PetroChina Pipeline Company, LangFang, HeBei, China
Min Xiong
R&D Center of PetroChina Pipeline Company, LangFang, HeBei, China
Jinyun Zhao
R&D Center of PetroChina Pipeline Company, LangFang, HeBei, China
Hongchao Wang
R&D Center of PetroChina Pipeline Company, LangFang, HeBei, China
Bin Xu
R&D Center of PetroChina Pipeline Company, LangFang, HeBei, China
DongLiang Yu
R&D Center of PetroChina Pipeline Company, LangFang, HeBei, China
Yi Sun
R&D Center of PetroChina Pipeline Company, LangFang, HeBei, China
Yongjun Cai
R&D Center of PetroChina Pipeline Company, LangFang, HeBei, China
Paper No:
IPC2010-31159, pp. 501-506; 6 pages
Published Online:
April 4, 2011
Citation
Wang, L, Xiong, M, Zhao, J, Wang, H, Xu, B, Yu, D, Sun, Y, & Cai, Y. "Research on Pipeline Leak Detection Method Based on Joint Pressure and Dynamic Pressure." Proceedings of the 2010 8th International Pipeline Conference. 2010 8th International Pipeline Conference, Volume 3. Calgary, Alberta, Canada. September 27–October 1, 2010. pp. 501-506. ASME. https://doi.org/10.1115/IPC2010-31159
Download citation file:
11
Views
Related Proceedings Papers
Related Articles
Simulation of Gas Pipelines Leakage Using Modified Characteristics Method
J. Energy Resour. Technol (June,2012)
An Efficient Methodology for the Reliability Analysis of Corroding Pipelines
J. Pressure Vessel Technol (August,2014)
Thermodynamic Analysis of Thermal Responses in Horizontal Wellbores
J. Energy Resour. Technol (May,2015)
Related Chapters
Liquid Pipeline Operation
Hydrocarbon Liquid Transmission Pipeline and Storage Systems
Pipeline Integrity and Security
Continuing and Changing Priorities of the ASME Boiler & Pressure Vessel Codes and Standards
Contamination and Impacts of Exploration and Production Waste Constituents
Guidebook for Waste and Soil Remediation: For Nonhazardous Petroleum and Salt Contaminated Sites