Proc. ASME. OMAE2020, Volume 1: Offshore Technology, V001T01A064, August 3–7, 2020
Paper No: OMAE2020-18717
.../diffraction analysis, decay tests and current coefficients. WF responses are very well predicted by standard radiation/diffraction linear analysis, therefore the focus is on the LF responses. LF motions are underpredicted by the uncalibrated numerical model. Calibration is performed by comparing simulations...