Background: Whole bone in vitro biomechanical compressive testing can be complicated by three factors: sample asymmetry, heterogeneous material properties, and unknown effective centroid location. Method of approach: The technique presented here facilitates the calculation of effective centroid position, modulus of elasticity and equivalent uniform strain magnitude for a cross section of bone from a simple whole bone compressive test. Simplification of section response to load is achieved through a combination of linear beam and simple planer geometry theory. The technique requires three longitudinal strain gauges be affixed around the test specimen cross section of interest, gauge position need not be determined. Sample loading is then accomplished using a simple four point loading jig. Results: Results of the technique are presented on an object with known elasticity and geometry, an aluminium tube, and seven pairs of equine third metacarpal whole bones. Conclusions: Average cross section modulus of elasticity, equivalent uniform cross section strain, and effective centroid locations were all predicted to within the range of published values. Employing the testing setup and analysis technique presented in this paper resulted in a significant savings in both implementation complexity and cost over previously available techniques.
Skip Nav Destination
e-mail: jruncima@uoguelph.ca
Article navigation
October 2005
Technical Papers
Determining Effective Centroid Position in Biomechanical Testing: A Technique for Simplifying Whole Bone Analysis
Gabrielle Whan,
Gabrielle Whan
School of Engineering,
University of Guelph
, Guelph, ON, Canada N1G 2W1
Search for other works by this author on:
R. John Runciman,
R. John Runciman
School of Engineering,
e-mail: jruncima@uoguelph.ca
University of Guelph
, Guelph, ON, Canada N1G 2W1
Search for other works by this author on:
Mark Hurtig
Mark Hurtig
Ontario Veterinary College,
University of Guelph
, Guelph, ON, Canada N1G 2W1
Search for other works by this author on:
Gabrielle Whan
School of Engineering,
University of Guelph
, Guelph, ON, Canada N1G 2W1
R. John Runciman
School of Engineering,
University of Guelph
, Guelph, ON, Canada N1G 2W1e-mail: jruncima@uoguelph.ca
Mark Hurtig
Ontario Veterinary College,
University of Guelph
, Guelph, ON, Canada N1G 2W1J Biomech Eng. Oct 2005, 127(5): 736-741 (6 pages)
Published Online: May 4, 2005
Article history
Received:
September 17, 2004
Revised:
May 4, 2005
Citation
Whan, G., Runciman, R. J., and Hurtig, M. (May 4, 2005). "Determining Effective Centroid Position in Biomechanical Testing: A Technique for Simplifying Whole Bone Analysis." ASME. J Biomech Eng. October 2005; 127(5): 736–741. https://doi.org/10.1115/1.1993663
Download citation file:
51
Views
Get Email Alerts
Cited By
Improvement in Active Cell Proliferation Area at Higher Permeability With Novel TPMS Lattice Structure
J Biomech Eng (November 2024)
Modeling Fatigue Failure of Cartilage and Fibrous Biological Tissues Using Constrained Reactive Mixture Theory
J Biomech Eng (December 2024)
A Numerical Study of Crack Penetration and Deflection at the Interface Between Peritubular and Intertubular Dentin
J Biomech Eng (December 2024)
Related Articles
Sensitivity of Multiple Damage Parameters to Compressive Overload in
Cortical Bone
J Biomech Eng (August,2005)
Response to Comment by Charles W. McCutchen
J Biomech Eng (August,2004)
Influence of Clinically Relevant Factors on the Immediate Biomechanical Surrounding for a Series of Dental Implant Designs
J Biomech Eng (March,2011)
Subject-Specific Finite Element Model of the Pelvis: Development, Validation and Sensitivity Studies
J Biomech Eng (June,2005)
Related Proceedings Papers
Related Chapters
Data Tabulations
Structural Shear Joints: Analyses, Properties and Design for Repeat Loading
Flexibility Analysis
Process Piping: The Complete Guide to ASME B31.3, Third Edition
Introduction and Definitions
Handbook on Stiffness & Damping in Mechanical Design