This paper reports the results of CFD analysis to cool the 30-W socketed CPU of a desktop computer with minimum air flow rate and minimum heat sink size. This was achieved using only the fan in the power supply for all air movement in the chassis. A duct was employed to direct the air flow over the CPU and then to the inlet air vents of the power supply. Use of this duct allowed more than 10°C reduction of the CPU case temperature, relative to an unducted design. The CFD analysis results were confirmed by experiment, and the predicted CPU case temperatures agreed within ±2.9°C of the experimental values for the ducted cases. This paper describes the methodology of CFD analysis for the heat sink/duct design, and describes experimental procedures to validate the predictions.
Skip Nav Destination
Article navigation
September 2001
Technical Papers
Identification of Minimum Air Flow Design for a Desktop Computer Using CFD Modeling
J. Y. Chang,
J. Y. Chang
Department of Mechanical and Nuclear Engineering, The Pennsylvania State University, University Park, PA 16802-1413
Search for other works by this author on:
C. W. Yu,
C. W. Yu
Department of Mechanical and Nuclear Engineering, The Pennsylvania State University, University Park, PA 16802-1413
Search for other works by this author on:
R. L. Webb
R. L. Webb
Department of Mechanical and Nuclear Engineering, The Pennsylvania State University, University Park, PA 16802-1413
Search for other works by this author on:
J. Y. Chang
Department of Mechanical and Nuclear Engineering, The Pennsylvania State University, University Park, PA 16802-1413
C. W. Yu
Department of Mechanical and Nuclear Engineering, The Pennsylvania State University, University Park, PA 16802-1413
R. L. Webb
Department of Mechanical and Nuclear Engineering, The Pennsylvania State University, University Park, PA 16802-1413
Contributed by the Electrical and Electronic Packaging Division for publication in the JOURNAL OF ELECTRONIC PACKAGING. Manuscript received at ASME Headquarters October 11, 2000. Associate Editor: R. Wirtz.
J. Electron. Packag. Sep 2001, 123(3): 225-231 (7 pages)
Published Online: October 11, 2000
Article history
Received:
October 11, 2000
Citation
Chang , J. Y., Yu , C. W., and Webb, R. L. (October 11, 2000). "Identification of Minimum Air Flow Design for a Desktop Computer Using CFD Modeling ." ASME. J. Electron. Packag. September 2001; 123(3): 225–231. https://doi.org/10.1115/1.1348012
Download citation file:
Get Email Alerts
Optimization of Micro-Pillars Electroplating Bonding Processes and Additives
J. Electron. Packag
Microbead Encapsulation for Protection of Electronic Components
J. Electron. Packag
Performance Analysis of a Brazed Plate Heat Exchanger During Condensation of R1233zd(E)
J. Electron. Packag (June 2025)
Related Articles
Analysis of Liquid-Cooled Heat Sink Used for Power Electronics Cooling
J. Thermal Sci. Eng. Appl (June,2011)
Compact Modeling of Forced Flow in Longitudinal Fin Heat Sinks With Tip Bypass
J. Electron. Packag (September,2003)
Foreword
J. Heat Transfer (January,2005)
Merits of Employing Foam Encapsulated Phase Change Materials for Pulsed Power Electronics Cooling Applications
J. Electron. Packag (June,2008)
Related Proceedings Papers
Related Chapters
Outlook
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Air Cooling and Heat Sinks
Thermal Management of Telecommunication Equipment, Second Edition
Air Cooling and Heat Sinks
Thermal Management of Telecommunications Equipment