The present study investigates the improvement in the performance of an absorption heat pump for residential space-conditioning due to the use of the ground as the heat source in the heating mode and the heat sink in the cooling mode. A baseline air-coupled single-effect ammonia-water heat pump is first designed to deliver 10.55 kW (36,000 Btu/h) of cooling load at the ARI rating conditions. Particular attention is paid to incorporating many realistic details of an operating system such as fuel combustion efficiencies of the burner, nonequilibrium conditions, and moist air processes in the air-coupled heat exchangers. A range of parametric studies is also conducted to investigate the variation in performance of this system with ambient conditions in the heating and cooling modes. The same system is then analyzed in a ground-coupled configuration. The instantaneous COP for the ground-coupled system is compared with the COP of the air-coupled system as a function of the time of the year and the corresponding variations in ambient and ground temperatures using 30-yr average climate data for various locations from the National Weather Service. Improvements in COP of up to 20 percent over the air-coupled system values (cooling mode COP of 0.495 at 35°C (95°F) and heating mode COP of 1.20 at 8.33°C (47°F)) are demonstrated in diverse geographic locations with widely varying heating and cooling loads. These improvements indicate that an efficient ground-coupled heat pump could be developed for residential space-conditioning applications using simple thermodynamic cycles and existing technology for the heat and mass exchange components.

1.
ASHRAE, 1995, Commercial/Institutional Ground-Source Heat Pump Engineering Manual, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
2.
DeVault, R. C., and Marsala, J., 1990, “Ammonia-Water Triple-Effect Absorption Cycle,” ASHRAE Transactions. Vol. 96, Part 1.
3.
Engler, M., Grossman, G., and Hellmann, H.-M., 1996, “Comparative Simulation and Investigation of Ammonia-Water Absorption Cycles for Heat Pump Applications,” Proceedings, International Absorption Heat Pump Conference, Montreal, Canada, September 17–20, pp. 209–219.
4.
Garimella
S.
,
Christensen
R. N.
, and
Petty
S. E.
,
1992
, “
Cycle Description and Performance Simulation of a Gas-Fired Hydronically Coupled Double-Effect Absorption Heat Pump System
,”
Recent Research In Heat Pump Design, Analysis, and Application
, ASME AES-Vol.
28
, pp.
7
14
.
5.
Garimella
S.
,
Christensen
R. N.
, and
Lacy
D.
,
1996
, “
Performance Evaluation of a Generator Absorber Heat Exchange Heat Pump
,”
Applied Thermal Engineering
, Vol.
16
, No.
7
, pp.
591
604
.
6.
Garimella, S., Lacy, D., and Stout, R. E., 1997, “Space-Conditioning Using Triple-effect Absorption Heat Pumps,” accepted for publication in Applied Thermal Engineering.
7.
Gommed
K.
, and
Grossman
G.
,
1990
, “
Performance Analysis of Staged Absorption Heat Pumps: Water-Lithium Bromide Systems
,”
ASHRAE Transactions
, Vol.
96
, Part 1, pp.
1590
1598
.
8.
Grossman, G., Wilk, M., and DeVault, R. C, 1994, “Simulation and Performance Analysis of Triple-Effect Absorption Cycles,” ASHRAE Transactions, Vol. 100, Part 1.
9.
Grossman, G., Zaltash, A., Adcock, P. W., and DeVault, R. C, 1995, “Simulating a 4-Effect Absorption Chiller,” ASHRAE Journal, June, pp. 45–53.
10.
Herold, K. E., Radermacher, R., and Klein, S. A., 1996, Absorption Chillers and Heat Pumps, CRC Press.
11.
Lvester
D. N.
, and
Shelton
S. V.
,
1994
, “
Varying Heat Exchanger Parameters in the Triple-Effect Absorption Cycle
,”
Proceedings, International Absorption Heat pump Conference
, New Orleans, LA, ASME AES-Vol.
31
, Jan., pp.
243
250
.
12.
McGahey
K.
,
Garimella
S.
,
Cook
F. B.
, and
Christensen
R. N.
,
1994
, “
Enhancement of th ORNL Absorption Model and Simulation of a Double-Effect Absorption Heat Pump
,”
Proceedings, International Absorption Heat Pump Conference
, New Orleans, LA, ASME AES-Vol.
31
, Jan, pp.
141
148
.
13.
NRECA Rural Electric Research Program, 1988, Closed-Loop Ground-Source Heat Pump Systems, Nov.
14.
Nielson
E.
, and
Den Braven
K.
,
1996
, “
Performance Prediction of a Sub-Slab Heat Exchanger for Geothermal Heat Pumps
,”
Proceedings, Advanced Energy Systems Division
, ASME AES-Vol.
36
, pp.
75
85
.
15.
Remund
C. P.
,
1994
, “
Thermal Performance Evaluation of Common Soils for Horizontal Ground Source Heat Pump Application
,”
Heat Pump and Refrigeration Systems Design, Analysis, and Applications
, ASME AES-Vol.
32
, pp.
45
62
.
16.
Remund
C. P.
, and
Schultz
S. C.
,
1995
, “
Performance of a Ground Source Heat Pump Coupled to Slinky Ground Heat Exchangers
,”
Heat Pump and Refrigeration Systems Design, Analysis and Applications
, ASME AES-Vol.
34
, pp.
75
88
.
17.
Wibbels
M.
, and
Den Braven
K.
,
1994
, “
The Effect of Cyclic Operation of a Horizontal Ground Loop on Ground Coupled Heat Pump Performance
,”
Heat Pump and Refrigeration Systems Design, Analysis, and Applications
, ASME AES-Vol.
32
, pp.
33
44
.
18.
Ziegler
F.
, and
Alefeld
G.
,
1994
, “
Comparison of Multi-Effect Absorption Cycles
,” Proceedings,
International Absorption Heat Pump Conference
, New Orleans, LA, ASME AES-Vol.
31
, Jan., pp.
257
264
.
This content is only available via PDF.
You do not currently have access to this content.