The present study investigates the improvement in the performance of an absorption heat pump for residential space-conditioning due to the use of the ground as the heat source in the heating mode and the heat sink in the cooling mode. A baseline air-coupled single-effect ammonia-water heat pump is first designed to deliver 10.55 kW (36,000 Btu/h) of cooling load at the ARI rating conditions. Particular attention is paid to incorporating many realistic details of an operating system such as fuel combustion efficiencies of the burner, nonequilibrium conditions, and moist air processes in the air-coupled heat exchangers. A range of parametric studies is also conducted to investigate the variation in performance of this system with ambient conditions in the heating and cooling modes. The same system is then analyzed in a ground-coupled configuration. The instantaneous COP for the ground-coupled system is compared with the COP of the air-coupled system as a function of the time of the year and the corresponding variations in ambient and ground temperatures using 30-yr average climate data for various locations from the National Weather Service. Improvements in COP of up to 20 percent over the air-coupled system values (cooling mode COP of 0.495 at 35°C (95°F) and heating mode COP of 1.20 at 8.33°C (47°F)) are demonstrated in diverse geographic locations with widely varying heating and cooling loads. These improvements indicate that an efficient ground-coupled heat pump could be developed for residential space-conditioning applications using simple thermodynamic cycles and existing technology for the heat and mass exchange components.
Skip Nav Destination
e-mail: garimella@wmich.edu
Article navigation
December 1997
Technical Papers
Absorption Heat Pump Performance Improvement Through Ground Coupling
S. Garimella
S. Garimella
Department of Mechanical and Aeronautical Engineering, Western Michigan University, Kalamazoo, MI 49008
e-mail: garimella@wmich.edu
Search for other works by this author on:
S. Garimella
Department of Mechanical and Aeronautical Engineering, Western Michigan University, Kalamazoo, MI 49008
e-mail: garimella@wmich.edu
J. Energy Resour. Technol. Dec 1997, 119(4): 242-249 (8 pages)
Published Online: December 1, 1997
Article history
Received:
July 13, 1997
Revised:
July 23, 1997
Online:
November 6, 2007
Citation
Garimella, S. (December 1, 1997). "Absorption Heat Pump Performance Improvement Through Ground Coupling." ASME. J. Energy Resour. Technol. December 1997; 119(4): 242–249. https://doi.org/10.1115/1.2794997
Download citation file:
Get Email Alerts
Cited By
Related Articles
Experimental Testing of a Thermoelectric-Based Hydronic Cooling and Heating Device With Transient Charging of Sensible Thermal Energy Storage Water Tank
J. Thermal Sci. Eng. Appl (December,2009)
Compact Diesel Engine Waste-Heat-Driven Ammonia–Water Absorption Heat Pump Modeling and Performance Maximization Strategies
J. Energy Resour. Technol (June,2022)
Performance of a Residential-Sized GAX Absorption Chiller
J. Energy Resour. Technol (September,2001)
Evaluation of Thermo-Active Foundations for Heating and Cooling Residential Buildings
J. Sol. Energy Eng (December,2016)
Related Chapters
Experimental Investigation of an Improved Thermal Response Test Equipment for Ground Source Heat Pump Systems
Inaugural US-EU-China Thermophysics Conference-Renewable Energy 2009 (UECTC 2009 Proceedings)
Threshold Functions
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Physiology of Human Power Generation
Design of Human Powered Vehicles