The last stage blades (LSBs) of low-pressure (LP) turbine power plants have been historically specified and designed on the basis of optimization studies by matching the turbine to the condenser/cooling system for a specified unit rating. LSB sizes for U.S. nuclear applications currently range from 38 in. to 52 in. for unit ratings of 600 MWe to 1200 MWe. LP turbine arrangements usually consist of two or three double-flow sections in parallel. Last stage end loadings (last stage mass flow divided by the last stage annulus area) vary from approximately , with corresponding unit loadings (electrical output in megawatts divided by last stage annulus area) of 1.1 . Several power plants have been upgrading/replacing their LP turbines. Considerations include efficiency, reliability, power uprates, operating license renewals (nuclear), aging, inspection, and maintenance. In some cases, LP turbine rotors are being replaced with new rotors, blading, and steam path. Others are replacing LP turbines with new and advanced designs incorporating improved technology, better materials, optimized steam paths, more efficient blading, longer LSB sizes, redesigned exhaust hoods, etc. Unlike the other stages in the LP turbine, the last stage performance is affected by both the upstream (load) and downstream (condenser) conditions. While the LP turbines are being upgraded or replaced, no major modifications or upgrades are being made to the condensers. To address vibration effects due to increased flows and velocities from power uprates, the condenser tubes may be staked. Circulating water pumps may or may not be upgraded depending upon the particular application. Consequently, while improvements in LP turbines lead to more efficient utilization of the available energy and higher output, the last stage performance may be out of synchronization with the existing condenser/cooling system. Undersized or oversized LSB sizes in relation to the unit rating and end loading may result in less than optimum performance depending upon the design and operating range of the condenser/cooling system. This paper examines the various factors that affect last stage performance of LP turbines. Using a case study, it discusses the relationships between the last stage, the unit rating, the end loading, and the operating range of the condenser/cooling system. It examines different last stage exhaust loss curves and provides recommendations for selection of LSB sizes for optimum performance.
Skip Nav Destination
Article navigation
March 2008
Research Papers
Last Stage Performance Considerations in Low-Pressure Turbines of Power Plants: A Case Study
Komandur S. Sunder Raj
Komandur S. Sunder Raj
President
Power & Energy Systems Services
, 880 Ridgewood Avenue, Oradell, NJ 07649
Search for other works by this author on:
Komandur S. Sunder Raj
President
Power & Energy Systems Services
, 880 Ridgewood Avenue, Oradell, NJ 07649J. Eng. Gas Turbines Power. Mar 2008, 130(2): 023004 (7 pages)
Published Online: January 22, 2008
Article history
Received:
October 14, 2006
Revised:
August 20, 2007
Published:
January 22, 2008
Citation
Sunder Raj, K. S. (January 22, 2008). "Last Stage Performance Considerations in Low-Pressure Turbines of Power Plants: A Case Study." ASME. J. Eng. Gas Turbines Power. March 2008; 130(2): 023004. https://doi.org/10.1115/1.2795781
Download citation file:
Get Email Alerts
Cited By
Shape Optimization of an Industrial Aeroengine Combustor to reduce Thermoacoustic Instability
J. Eng. Gas Turbines Power
Dynamic Response of A Pivot-Mounted Squeeze Film Damper: Measurements and Predictions
J. Eng. Gas Turbines Power
Review of The Impact Of Hydrogen-Containing Fuels On Gas Turbine Hot-Section Materials
J. Eng. Gas Turbines Power
Effects of Lattice Orientation Angle On Tpms-Based Transpiration Cooling
J. Eng. Gas Turbines Power
Related Articles
Importance of Auxiliary Power Consumption for Combined Cycle Performance
J. Eng. Gas Turbines Power (April,2011)
Feasibility Study of an Innovative Dry-Cooling System With Phase-Change Material Storage for Concentrated Solar Power Multi-MW Size Power Plant
J. Sol. Energy Eng (August,2011)
Leaving-Velocity and Exhaust Loss in Steam Turbines
Trans. ASME (June,1934)
A Computational Model of a Power Plant Steam Condenser
J. Energy Resour. Technol (March,2001)
Related Proceedings Papers
Related Chapters
Engineering and Physical Modeling of Power Plant Cooling Systems
Thermal Power Plant Cooling: Context and Engineering
Combined Cycle Power Plant
Energy and Power Generation Handbook: Established and Emerging Technologies
Introduction
Consensus on Operating Practices for Control of Water and Steam Chemistry in Combined Cycle and Cogeneration