The output and efficiency of gas turbines are reduced significantly during the summer, especially in areas where the daytime temperature reaches as high as 50°C. Gas turbine inlet fogging and overspray has been considered a simple and cost-effective method to increase the power output. One of the most important issues related to inlet fogging is to determine the most effective location of the fogging device by determining (a) how many water droplets actually evaporate effectively to cool down the inlet air instead of colliding on the wall or coalescing and draining out (i.e., fogging efficiency), and (b) quantifying the amount of nonevaporated droplets that may reach the compressor bellmouth to ascertain the erosion risk for compressor airfoils if wet compression is to be avoided. When the silencer is installed, there is an additional consideration for placing the fogging device upstream or downstream of the silencer baffles. Placing arbitrarily the device upstream of the silencer can cause the silencer to intercept water droplets on the silencer baffles and lose cooling effectiveness. This paper employs computational fluid dynamics (CFD) to investigate the water droplet transport and cooling effectiveness with different spray locations such as before and after the silencer baffles. Analysis on the droplet history (trajectory and size) is employed to interpret the mechanism of droplet dynamics under influence of acceleration, diffusion, and body forces when the flow passes through the baffles and duct bent. The results show that, for the configuration of the investigated duct, installing the fogging system upstream of the silencer is about 3 percentage points better in evaporation effectiveness than placing it downstream of the silencer, irrespective of whether the silencer consists of a single row of baffles or two rows of staggered baffles. The evaporation effectiveness of the staggered silencer is about 0.8 percentage points higher than the single silencer. The pressure drop of the staggered silencer is 6.5% higher than the single silencer.
Skip Nav Destination
e-mail: jrkhan@uno.edu
e-mail: twang@uno.edu
Article navigation
February 2012
Research Papers
Investigation of Cooling Effectiveness of Gas Turbine Inlet Fogging Location Relative to the Silencer
Jobaidur R. Khan,
Jobaidur R. Khan
Energy Conversion and Conservation Center,
e-mail: jrkhan@uno.edu
University of New Orleans
, New Orleans, LA 70148-2220
Search for other works by this author on:
Ting Wang,
Ting Wang
Energy Conversion and Conservation Center,
e-mail: twang@uno.edu
University of New Orleans
, New Orleans, LA 70148-2220
Search for other works by this author on:
Mustapha Chaker
Mustapha Chaker
Search for other works by this author on:
Jobaidur R. Khan
Energy Conversion and Conservation Center,
University of New Orleans
, New Orleans, LA 70148-2220e-mail: jrkhan@uno.edu
Ting Wang
Energy Conversion and Conservation Center,
University of New Orleans
, New Orleans, LA 70148-2220e-mail: twang@uno.edu
Mustapha Chaker
J. Eng. Gas Turbines Power. Feb 2012, 134(2): 022001 (9 pages)
Published Online: December 16, 2011
Article history
Received:
April 12, 2011
Revised:
April 13, 2011
Online:
December 16, 2011
Published:
December 16, 2011
Citation
Khan, J. R., Wang, T., and Chaker, M. (December 16, 2011). "Investigation of Cooling Effectiveness of Gas Turbine Inlet Fogging Location Relative to the Silencer." ASME. J. Eng. Gas Turbines Power. February 2012; 134(2): 022001. https://doi.org/10.1115/1.4004044
Download citation file:
Get Email Alerts
Cited By
Image-based flashback detection in a hydrogen-fired gas turbine using a convolutional autoencoder
J. Eng. Gas Turbines Power
Fuel Thermal Management and Injector Part Design for LPBF Manufacturing
J. Eng. Gas Turbines Power
An investigation of a multi-injector, premix/micromix burner burning pure methane to pure hydrogen
J. Eng. Gas Turbines Power
Related Articles
Overspray and Interstage Fog Cooling in Gas Turbine Compressor Using Stage-Stacking Scheme—Part I: Development of Theory and Algorithm
J. Thermal Sci. Eng. Appl (September,2010)
Influence of High Fogging Systems on Gas Turbine Engine Operation and Performance
J. Eng. Gas Turbines Power (January,2006)
Three-Dimensional Modeling for Wet Compression in a Single Stage Compressor Including Liquid Particle Erosion Analysis
J. Eng. Gas Turbines Power (January,2011)
The Effect of Water Injection on Multispool Gas Turbine
Behavior
J. Eng. Gas Turbines Power (January,2006)
Related Proceedings Papers
Related Chapters
Control and Operational Performance
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Thermodynamic Performance
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Combined Cycle Power Plant
Energy and Power Generation Handbook: Established and Emerging Technologies