The effects of array configuration and pin-endwall fillet on the heat transfer and pressure drop of short pin-fin arrays are investigated experimentally. The pin-fin element with endwall fillet, typical in actual turbine cooling applications, is modeled by a spool-like cylinder. The arrays studied include an in-line and a staggered array, each having seven rows of five pins. These arrays have the same geometric parameters, i.e., H/D = 1, S/D = X/D = 2.5, and the Reynolds number ranging from 5 × 103 to 3 × 104. One of the present results shows that the staggered array always has a higher array-averaged heat transfer coefficient than its in-line counterpart. However, the pressure drop for the staggered array is higher compared to the in-line configuration. These trends are unaffected by the existence of the pin-endwall fillet. Another significant finding is that an array with pin-endwall fillet generally produces lower heat transfer coefficient and higher pressure drop than that without endwall fillet. This leads to the conclusion that pin-endwall fillet is undesirable for heat transfer augmentation. In addition, nai¨ve use of the heat transfer results obtained with perfectly circular cylinders tends to overestimate the pin-fin cooling capability in the actual turbine. The effects of endwall fillet on the array heat transfer and pressure drop are much more pronounced for the staggered array than for the inline array; however, they diminish as the Reynolds number increases.
Skip Nav Destination
Article navigation
Research Papers
Heat Transfer and Pressure Drop for Short Pin-Fin Arrays With Pin-Endwall Fillet
M. K. Chyu
M. K. Chyu
Department of Mechanical Engineering, Carnegie Mellon University, Pittsburgh, PA 15213
Search for other works by this author on:
M. K. Chyu
Department of Mechanical Engineering, Carnegie Mellon University, Pittsburgh, PA 15213
J. Heat Transfer. Nov 1990, 112(4): 926-932 (7 pages)
Published Online: November 1, 1990
Article history
Received:
March 15, 1989
Revised:
February 27, 1990
Online:
May 23, 2008
Citation
Chyu, M. K. (November 1, 1990). "Heat Transfer and Pressure Drop for Short Pin-Fin Arrays With Pin-Endwall Fillet." ASME. J. Heat Transfer. November 1990; 112(4): 926–932. https://doi.org/10.1115/1.2910502
Download citation file:
Get Email Alerts
Cited By
Related Articles
Experimental Study on Forced Convection Heat Transfer Inside Horizontal Tubes in an Absorption/Compression Heat Pump
J. Heat Transfer (October,2002)
Heat Transfer and Pressure Drop Characteristics of an Assembly of Partially Segmented Plates
J. Heat Transfer (February,1989)
Evaluation of the Stagnation Point Region Overshoot
J. Heat Transfer (February,1992)
Regional Heat Transfer in Two-Pass and Three-Pass Passages With 180-deg Sharp Turns
J. Heat Transfer (February,1991)
Related Proceedings Papers
Related Chapters
Hydraulic Resistance
Heat Transfer & Hydraulic Resistance at Supercritical Pressures in Power Engineering Applications
Hitting the Wall
Hot Air Rises and Heat Sinks: Everything You Know about Cooling Electronics Is Wrong
Heat Transfer Enhancement by Using Nanofluids in Laminar Forced Convection Flows Considering Variable Properties
Proceedings of the 2010 International Conference on Mechanical, Industrial, and Manufacturing Technologies (MIMT 2010)