The rat tail intervertebral disc has emerged as an important model to examine the mechanisms for mechanically induced degeneration and remodeling. Previous methods used to apply high precision axial compressive loading to a rat tail intervertebral disc in vivo either required anesthesia, or the permanent mounting of a loading device to the animal, and were not well described in the literature. Therefore, a new device to apply compressive loading to the rat tail intervertebral disc was developed and validated. The rat tail compressive loading system utilized a pneumatically driven device weighing , and was capable of delivering a sinusoidal or square waveform at frequencies up to . The system improved on previous methods in its modular construction, relative ease of fabrication, compatibility with existing tail model technology and overall cost effectiveness. The removable system eliminated the need for anesthesia and through a modular, cost effective, design allowed for the simultaneous loading of multiple animals. This system expanded the ability to accurately, ethically, and efficiently apply dynamic compressive loads to the rat tail intervertebral disc for extended periods of time in order to address questions related to disc mechanobiology.
Skip Nav Destination
e-mail: james.iatridis@uvm.edu
Article navigation
March 2007
Research Papers
A Removable Precision Device for In-Vivo Mechanical Compression of Rat Tail Intervertebral Discs
Justin M. Stinnett-Donnelly,
Justin M. Stinnett-Donnelly
School of Engineering,
College of Engineering and Mathematical Sciences
, Burlington, VT 05405
Search for other works by this author on:
Jeffrey J. MacLean,
Jeffrey J. MacLean
School of Engineering,
College of Engineering and Mathematical Sciences
, Burlington, VT 05405
Search for other works by this author on:
James C. Iatridis
James C. Iatridis
School of Engineering,
e-mail: james.iatridis@uvm.edu
College of Engineering and Mathematical Sciences
, Burlington, VT 05405
Search for other works by this author on:
Justin M. Stinnett-Donnelly
School of Engineering,
College of Engineering and Mathematical Sciences
, Burlington, VT 05405
Jeffrey J. MacLean
School of Engineering,
College of Engineering and Mathematical Sciences
, Burlington, VT 05405
James C. Iatridis
School of Engineering,
College of Engineering and Mathematical Sciences
, Burlington, VT 05405e-mail: james.iatridis@uvm.edu
J. Med. Devices. Mar 2007, 1(1): 56-61 (6 pages)
Published Online: August 14, 2006
Article history
Received:
April 8, 2006
Revised:
August 14, 2006
Citation
Stinnett-Donnelly, J. M., MacLean, J. J., and Iatridis, J. C. (August 14, 2006). "A Removable Precision Device for In-Vivo Mechanical Compression of Rat Tail Intervertebral Discs." ASME. J. Med. Devices. March 2007; 1(1): 56–61. https://doi.org/10.1115/1.2355692
Download citation file:
Get Email Alerts
Cited By
Related Articles
Development of a Force-Driven Distractor for Distraction Osteogenesis
J. Med. Devices (December,2011)
Design of a Compliant Steerable Arthroscopic Punch
J. Med. Devices (June,2010)
Mechanical Design for Modularity of Laparoscopic Tools
J. Med. Devices (June,2008)
Related Proceedings Papers
Related Chapters
mDFA Human Empirical Results
Modified Detrended Fluctuation Analysis (mDFA)
Spherical SOFM: Implications for Forensics and Craniofacial Surgery
Intelligent Engineering Systems through Artificial Neural Networks
Introduction and scope
Impedimetric Biosensors for Medical Applications: Current Progress and Challenges