Background. Cochlear implants have become an accepted and successful treatment for profound sensorineural deafness in both children and adults. Essential to the effective and efficient localized stimulation of the auditory nerves, is the position of the implant electrode array stimulating sites within the scala tympani (ST). However, the small size, delicate internal structures and helical shape of the cochlear chambers complicate the matter of precise positioning of the implant electrode array. The design, fabrication process, and in vitro testing of a fluid actuator to steer a thin-film electrode array is presented. The application chosen to show feasibility is for a cochlear implant, however, the actuator might be used for cortical electrode arrays, for example. Method of Approach. The actuator functions by a change of internal fluid pressure within one or more flattened and curled polymer microtubes, expanding the highly elliptical cross section of each tube thereby stiffening it and causing a change in its curling radius. The straightening from an initially helical shape allows insertion of an attached electrode array into the basal end of the in vitro cochlea and as the insertion proceeds the pressure is decreased allowing the straightened electrode array to controllably return to its initial helical shape. The allowable envelope of the scala tympani of a guinea pig was determined from published data and the actuator was designed and fabricated accordingly. Results. Multiple actuators were fabricated and tested in vitro. The insertion tests helped to confirm the viability of using this type of actuation to facilitate the insertion of an electrode array into the ST. These tests were performed in a minimal amount of time and often on the first attempt. The actuator reached the furthest extent of the in vitro cavity and achieved a position adjacent to the modiolus. Conclusions. In vitro insertion tests show that the actuator can deliver a thin-film electrode array to a depth of more than one turn into the in vitro scala tympani within a few minutes under open-loop, manual control.
Skip Nav Destination
e-mail: craig@mtu.edu
Article navigation
March 2007
Research Papers
A Fluid Actuator for Thin-Film Electrodes
Benjamin Arcand,
Benjamin Arcand
Boston Scientific
, 1 Scimed Place, Maple Grove, MN 55331 and Mechanical Engineering—Engineering Mechanics Department, Michigan Center for Wireless Integrated Microsystems, Michigan Technological University
, Houghton, MI 49931
Search for other works by this author on:
Sudeep Shyamsunder,
Sudeep Shyamsunder
Mechanical Engineering—Engineering Mechanics Department, Michigan Center for Wireless Integrated Microsystems,
Michigan Technological University
, Houghton, MI 49931
Search for other works by this author on:
Craig Friedrich
Craig Friedrich
Mechanical Engineering—Engineering Mechanics Department, Michigan Center for Wireless Integrated Microsystems,
e-mail: craig@mtu.edu
Michigan Technological University
, Houghton, MI 49931
Search for other works by this author on:
Benjamin Arcand
Boston Scientific
, 1 Scimed Place, Maple Grove, MN 55331 and Mechanical Engineering—Engineering Mechanics Department, Michigan Center for Wireless Integrated Microsystems, Michigan Technological University
, Houghton, MI 49931
Sudeep Shyamsunder
Mechanical Engineering—Engineering Mechanics Department, Michigan Center for Wireless Integrated Microsystems,
Michigan Technological University
, Houghton, MI 49931
Craig Friedrich
Mechanical Engineering—Engineering Mechanics Department, Michigan Center for Wireless Integrated Microsystems,
Michigan Technological University
, Houghton, MI 49931e-mail: craig@mtu.edu
J. Med. Devices. Mar 2007, 1(1): 70-78 (9 pages)
Published Online: August 28, 2006
Article history
Received:
December 6, 2005
Revised:
August 28, 2006
Citation
Arcand, B., Shyamsunder, S., and Friedrich, C. (August 28, 2006). "A Fluid Actuator for Thin-Film Electrodes." ASME. J. Med. Devices. March 2007; 1(1): 70–78. https://doi.org/10.1115/1.2358357
Download citation file:
Get Email Alerts
Cited By
Related Articles
A Manual Insertion Mechanism for Percutaneous Cochlear Implantation
J. Med. Devices (June,2010)
Small-Scale Hydraulics for Human Assist Devices
J. Med. Devices (June,2011)
Improving the Performance of Implantable Electrostimulation Devices Using Electrically Conducting Polymers
J. Med. Devices (June,2011)
Machines for Life
Mechanical Engineering (December,2007)
Related Proceedings Papers
Related Chapters
Cubic Lattice Structured Multi Agent Based PSO Approach for Optimal Power Flows with Security Constraints
International Conference on Software Technology and Engineering, 3rd (ICSTE 2011)
Part 2, Section II—Materials and Specifications
Companion Guide to the ASME Boiler and Pressure Vessel Code, Volume 1, Third Edition
Part 2, Section II—Materials and Specifications
Companion Guide to the ASME Boiler & Pressure Vessel Code, Volume 1, Second Edition