This paper presents the preliminary development of a novel cryoablation catheter for the delivery of cryo-energy and complimentary pharmacological agents selected to improve lesion formation. The described prototype uses a commercially available cryoablation catheter with a deployable needle injection catheter grafted onto it. The device would be used in endocardial ablation of thick structures and would inject an adjuvant at the desired depth prior to cryotherapy delivery. Adjuvants have been investigated previously to increase the “kill zone” of an ablation lesion and can minimize the zone of incomplete death near the iceball edge. This makes visualization of the iceball via ultrasound a better predictor for lesion size and progression. Transmurality of a lesion can be essential for a clinical ablation procedure to have long-term effectiveness. The secondary goal of such a device may be to increase energy transfer via the metal needle in the myocardium, so to further aid in the creation of transmural lesions in thick tissues (e.g., the ventricles). Added embodiments of such therapeutic devices would be to also have electrical pacing/sensing capabilities and/or temperature monitoring capabilities at the tip of the needle. Such features would likely provide a physician with more precise information regarding lesion progressions and efficacies. One potential device design could therefore have two temperature sensors, one at the ablative tip and one at the needle tip. This will allow the user to monitor how far and how fast the lesion has advanced into the myocardium at the preset depth of the needle. After the lesion is formed, entrance and exit block tests could then be used to evaluate the ability of the lesion to block electrical propagation. A unique feature of this catheter design approach is the method of active deployment. The physician will preset a desired needle deployment depth and then navigate the catheter to the location of treatment. Next, the cryocatheter would be positioned and frozen to the desired location of the endocardium, when appropriate, the needle would then be deployed, perhaps by first applying a rf energy to warm the system within the created iceball so to allow needle to be actively plunged into the myocardium. Subsequently, the contact of the needle to the cryocatheter system will rapidly cool the needle within the engaged myocardium. This approach could potentially reduce the risks of perforations and ensure consistent deployment depths. As found in the literature, and during preliminary testing, lesion size can be readily increased using the focal delivery of a high NaCl infusion, prior to energy application. We consider here that it should be possible to create the final embodiments of such devices with additional pacing/sensing, temperature monitoring, and active deployment: This should be technologically feasible using commercially available products and stereolithography (SLA) rapid prototyping.
Skip Nav Destination
Article navigation
Design Of Medical Devices Conference Abstracts
Development of an Endocardial Cryoablation Catheter for Concomitant Delivery of Cryogenic Treatment and Adjuvants
John C. Bischof
John C. Bischof
University of Minnesota
Search for other works by this author on:
Ryan Goff
University of Minnesota
Paul A. Iaizzo
University of Minnesota
John C. Bischof
University of Minnesota
J. Med. Devices. Jun 2011, 5(2): 027520 (1 pages)
Published Online: June 13, 2011
Article history
Online:
June 13, 2011
Published:
June 13, 2011
Citation
Goff, R., Iaizzo, P. A., and Bischof, J. C. (June 13, 2011). "Development of an Endocardial Cryoablation Catheter for Concomitant Delivery of Cryogenic Treatment and Adjuvants." ASME. J. Med. Devices. June 2011; 5(2): 027520. https://doi.org/10.1115/1.3590386
Download citation file:
1,173
Views
Get Email Alerts
Cited By
Context-Driven Design of a Laparoscopic Instrument Cleaner for Use in Rural Low-Resource Hospitals
J. Med. Devices (March 2025)
Controlled Ice Nucleation With a Sand-PDMS Film Device Enhances Cryopreservation of Mouse Preantral Ovarian Follicles
J. Med. Devices (December 2024)
Review of Blood and Fluid Warming Methods
J. Med. Devices (December 2024)
Related Articles
Design of a Motion Compensated Tissue Resection Catheter for Beating Heart Cardiac Surgery
J. Med. Devices (June,2011)
Low-Intensity Ultrasound Alleviates Osteoarthritis In Vitro and in a Rabbit Model
J. Med. Devices (June,2011)
Wireless Recharging of Implanted Batteries via Ultrasound
J. Med. Devices (June,2009)
Design of a Catheter-Based Device for Performing Percutaneous Chordal-Cutting Procedures
J. Med. Devices (June,2009)
Related Proceedings Papers
Related Chapters
Insight into Automated Segmentation Using Deformable Registation in 4D Radiotherapy
International Conference on Computer Technology and Development, 3rd (ICCTD 2011)
PWM Speed Control of DC Motor by Temperature Sensor
International Conference on Computer Technology and Development, 3rd (ICCTD 2011)
Reservoir Water Level Detection Based on Optical Fiber Temperature Sensor
International Conference on Advanced Computer Theory and Engineering (ICACTE 2009)