We present a fuzzy rule-based system for epileptic seizure onset detection. Two features based on temporal evolution of seizure in electroencephalogram (EEG) were extracted from intracranial EEG (iEEG) recordings. Features extracted from multichannel EEGs were combined using fuzzy algorithms in feature domain as well as in spatial (channels) domain. Fuzzy rules were derived from experts’ knowledge and reasoning. Finally, a predefined threshold was used to make the final decision. A total of 40.46 h of iEEG recordings (obtained from Freiburg Seizure Prediction EEG database) selected from 13 patients having 19 seizures was used for the system evaluation. The overall detection rate of 100% was achieved with false detection rate of 0.275/h and the average detection latency of 26.858 seconds.
Skip Nav Destination
Article navigation
Design Of Medical Devices Conference Abstracts
An Approach to Seizure Onset Detection Using Fuzzy Logic Based on Seizure Evolution in Intracranial EEG
Reza Fazel-Rezai
Reza Fazel-Rezai
University of North Dakota
Search for other works by this author on:
Ahmed Rabbi
University of North Dakota
Reza Fazel-Rezai
University of North Dakota
J. Med. Devices. Jun 2011, 5(2): 027537 (1 pages)
Published Online: June 15, 2011
Article history
Online:
June 15, 2011
Published:
June 15, 2011
Citation
Rabbi, A., and Fazel-Rezai, R. (June 15, 2011). "An Approach to Seizure Onset Detection Using Fuzzy Logic Based on Seizure Evolution in Intracranial EEG." ASME. J. Med. Devices. June 2011; 5(2): 027537. https://doi.org/10.1115/1.3591388
Download citation file:
Get Email Alerts
Cited By
Context-Driven Design of a Laparoscopic Instrument Cleaner for Use in Rural Low-Resource Hospitals
J. Med. Devices (March 2025)
Controlled Ice Nucleation With a Sand-PDMS Film Device Enhances Cryopreservation of Mouse Preantral Ovarian Follicles
J. Med. Devices (December 2024)
Review of Blood and Fluid Warming Methods
J. Med. Devices (December 2024)
Related Articles
An Advanced Patient Lift and Transfer Device for the Home
J. Med. Devices (March,2010)
Design of a Dynamic Stabilization Spine Implant
J. Med. Devices (June,2009)
Intelligent Image-Based Gas-Liquid Two-Phase Flow Regime Recognition
J. Fluids Eng (June,2012)
Variable Self-Optimizing Cochlear Model for Heart Murmur Detection/Classification
J. Med. Devices (June,2009)
Related Proceedings Papers
Related Chapters
Feature Extraction and Classification of EEG Signal
International Conference on Mechanical Engineering and Technology (ICMET-London 2011)
A Review of Most Current Feature Extraction Methods for EEG Signal Processing
International Conference on Computer and Automation Engineering, 4th (ICCAE 2012)
Interval Type-2 Fuzzy Logic for Improving Feature Extraction and Response Integration in Modular Neural Networks for Image Recognition
Intelligent Engineering Systems Through Artificial Neural Networks, Volume 17