The intercooled cycle (IC) is a simplified novel proposal for generation IV nuclear power plants (NPP) based on studies demonstrating efficiencies of over 45%. As an alternative to the simple cycle recuperated (SCR) and the intercooled cycle recuperated (ICR), the main difference in configuration is no recuperator, which reduces its size. It is expected that the components of the IC will not operate at optimum part power due to seasonal changes in ambient temperature and grid prioritization for renewable sources. Thus, the ability to demonstrate viable part load performance becomes an important requirement. The main objective of this study is to derive off-design points (ODPs) for a temperature range of −35 °C to 50 °C and core outlet temperatures (COTs) between 750 °C and 1000 °C. The ODPs have been calculated using a tool designed for this study. Based on the results, the intercooler changes the mass flow rate and compressor pressure ratio (PR). However, a drop of ∼9% in plant efficiency, in comparison to the ICR (6%) was observed for pressure losses of up to 5%. The reactor pressure losses for IC have the lowest effect on plant cycle efficiency in comparison to the SCR and ICR. Characteristic maps are created to support first-order calculations. It is also proposed to consider the intercooler pressure loss as a handle for ODP performance. The analyses brings attention to the IC an alternative cycle and aids development of cycles for generation IV NPPs specifically gas-cooled fast reactors (GFRs) and very-high-temperature reactors (VHTRs), using helium.

References

1.
Locatelli
,
G.
,
Mancini
,
M.
, and
Todeschini
,
N.
,
2013
, “
Generation IV Nuclear Reactors: Current Status and Future Prospects
,”
Energy Policy
,
61
, pp.
1503
1520
.
2.
Bhargava
,
R. K.
,
Bianchi
,
M.
,
Pascale
,
A. D.
,
Montenegro
,
G. N.
, and
Peretto
,
A.
,
2007
, “
Gas Turbine Based Power Cycles—A State-of-the-Art Review
,”
Challenges of Power Engineering and Environment
,
Springer
,
Berlin
.
3.
Gad-Briggs
,
A.
, and
Pilidis
,
P.
,
2017
, “
Analyses of the Off-Design Point Performance of a High Pressure Ratio Intercooled Brayton Helium Gas Turbine Cycle for Generation IV Nuclear Power Plants
,”
ASME
Paper No. ICONE25-67715.
4.
Gad-Briggs
,
A.
,
Pilidis
,
P.
, and
Nikolaidis
,
T.
,
2017
, “
Analyses of a High Pressure Ratio Intercooled Direct Brayton Helium Gas Turbine Cycle for Generation IV Reactor Power Plants
,”
ASME J. Nucl. Eng. Radiat. Sci.
,
3
(
1
), p.
011021
.
5.
Gad-Briggs
,
A.
,
Pilidis
,
P.
, and
Nikolaidis
,
T.
,
2017
, “
A Review of the Turbine Cooling Fraction for Very High Turbine Entry Temperature Helium Gas Turbine Cycles for Generation IV Reactor Power Plants
,”
ASME J. Nucl. Eng. Radiat. Sci.
,
3
(
2
), p.
021007
.
6.
Gad-Briggs
,
A.
, and
Pilidis
,
P.
,
2017
, “
Analyses of Off-Design Point Performances of Simple and Intercooled Brayton Helium Recuperated Gas Turbine Cycles for Generation IV Nuclear Power Plants
,”
ASME
Paper No. ICONE25-67714.
7.
Carre
,
F.
,
Yvon
,
P.
,
Anzieu
,
P.
,
Chauvin
,
N.
, and
Malo
,
J.-Y.
,
2010
, “
Update of the French R&D Strategy on Gas-Cooled Reactors
,”
Nucl. Eng. Des.
,
240
(
10
), pp.
2401
2408
.
8.
Gad-Briggs
,
A.
, and
Pilidis
,
P.
,
2017
, “
Analyses of Simple and Intercooled Recuperated Direct Brayton Helium Gas Turbine Cycles for Generation IV Reactor Power Plants
,”
ASME J. Nucl. Eng. Radiat. Sci.
,
3
(
1
), p.
011017
.
9.
Pradeepkumar
,
K. N.
,
Tourlidakis
,
A.
, and
Pilidis
,
P.
,
2001
, “
Analysis of 115 MW, 3-Shaft, Helium Brayton Cycle Using Nuclear Heat Source
,”
ASME
Paper No. 2001-GT-0523.
10.
Pradeepkumar
,
K. N.
,
Tourlidakis
,
A.
, and
Pilidis
,
P.
,
2001
, “
Design and Performance Review of PBMR Closed Cycle Gas Turbine Plant in South Africa
,”
International Joint Power Generation Conference
, New Orleans, LA, June 4–7.
11.
Pradeepkumar
,
K. N.
,
Tourlidakis
,
A.
, and
Pilidis
,
P.
,
2001
, “
Performance Review: PBMR Closed Cycle Gas Turbine Power Plant
,”
Technical Committee Meeting on HTGR—Power Conversion Systems
, Palo Alto, CA, Nov. 14–16, pp.
99
112
.http://www.iaea.org/inis/collection/NCLCollectionStore/_Public/32/047/32047835.pdf?r=1
12.
Gad-Briggs
,
A.
,
Pilidis
,
P.
, and
Nikolaidis
,
T.
,
2017
, “
Analyses of the Control System Strategies and Methodology for Part Power Control of the Simple and Intercooled Recuperated Brayton Helium Gas Turbine Cycles for Generation IV Nuclear Power Plants
,”
ASME J. Nucl. Eng. Radiat. Sci.
,
3
(
4
), p.
041016
.
13.
Gad-Briggs
,
A.
,
Pilidis
,
P.
, and
Nikolaidis
,
T.
,
2017
, “
Analyses of the Load Following Capabilities of Brayton Helium Gas Turbine Cycles for Generation IV Nuclear Power Plants
,”
ASME J. Nucl. Eng. Radiat. Sci.
,
3
(
4
), p.
041017
.
14.
Kyprianidis
,
K. G.
,
2010
, “
Multi-Disciplinary Conceptual Design of Future Jet Engine Systems
,”
Ph.D. thesis
, Cranfield University, Cranfield, UK.https://dspace.lib.cranfield.ac.uk/handle/1826/8041
15.
Walsh
,
P. P.
, and
Fletcher
,
P.
,
2004
,
Gas Turbine Performance
, 2nd ed.,
Blackwell Publishing
, Oxford,
UK
.
16.
Gad-Briggs
,
A.
,
Nikolaidis
,
T.
, and
Pilidis
,
P.
,
2017
, “
Analyses of the Effect of Cycle Inlet Temperature on the Precooler and Plant Efficiency of the Simple and Intercooled Helium Gas Turbine Cycles for Generation IV Nuclear Power Plants
,”
Appl. Sci.
,
7
(
4
), p.
319
.
You do not currently have access to this content.