In this publication, the detailed spectral characterization of the concentrated radiation of PSI’s 50 kW xenon arc lamp based solar simulator (HFSS) is reported. Spectra are presented for the range of 350–1600 nm recorded at different radial distances from the position of maximum concentration, i.e., from the center of the spot. The analysis shows that the relative intensity of the short wavelength region decreases with increasing radial distance from the center of the spot. At the same time, the relative contribution of the xenon emission lines increases. All spectra can be decomposed into a broad background described by a blackbody spectrum with a temperature of T = 6000 ± 200 K and the characteristic line spectrum of xenon.
Issue Section:
Research Papers
References
1.
Petrasch
, J.
, Coray
, P.
, Meier
, A.
, Brack
, M.
, Haberling
, P.
, Wuillemin
, D.
, and Steinfeld
, A.
, 2007, “A Novel 50 kW 11,000 Suns High-Flux Solar Simulator Based on an Array of Xenon Arc Lamps
,” ASME J. Sol. Energy
, 129
(4
), pp. 405
–411
.2.
Krueger
, K. R.
, Davidson
, J. H.
, and Lipinski
, W.
, 2011, “Design of a New 45 kW(e) High-Flux Solar Simulator for High-Temperature Solar Thermal and Thermochemical Research
,” ASME J. Sol. Energy
, 133
(1
), p. 110130
.3.
Dibowski
, G.
, Neumann
, A.
, Rietbrock
, P.
, Willsch
, P.
, Säck
, J.-P.
, and Funken
, K.-H.
, 2007, “Der neue Hochleistungsstrahler des DLR—Grundlagen, Technik, Anwendung
,” 10. Kölner Sonnenkolloquium.4.
Hernandez
, D.
, Olalde
, G.
, Gineste
, J. M.
, and Gueymard
, C.
, 2004, “Analysis and Experimental Results of Solar-Blind Temperature Measurements in Solar Furnaces
,” ASME J. Sol. Energy
, 126
(1
), pp. 645
–653
.5.
Hein
, M.
, Dimroth
, F.
, Siefer
, G.
, and Bett
, A. W.
, 2003, “Characterisation of a 300x Photovoltaic Concentrator System With One-Axis Tracking
,” Sol. Energy Mater. Sol. Cells
, 75
(1–2
), pp. 277
–283
.6.
Verlinden
, P. J.
, Lewandowski
, A.
, and Lasich
, J. B.
, 2006, “Performance and Reliability of a 30-kW Triple-Junction Photovoltaic Receiver for 500x Concentrator Dish or Central Receiver Applications
,” Proc. SPIE
6339
, 633907
.7.
Bard
, A. J.
, and Fox
, M. A.
, 1995, “Artificial Photosynthesis: Solar Splitting of Water to Hydrogen and Oxygen
,” Acc. Chem. Res.
, 28
(3
), pp. 141
–145
.8.
Saladin
, F.
, Forss
, L.
, and Kamber
, I.
, 1995, “Photosynthesis of CH4 at a TiO2 Surface From Gaseous H2O and CO2
,” J. Chem. Soc., Chem. Commun.
, issue 5
, pp. 533
–534
.9.
Saladin
, F.
, and Alxneit
, I.
, 1997, “Temperature Dependence of the Photochemical Reduction of CO2 in the Presence of H2O at the Solid/Gas Interface of TiO2
,” J. Chem. Soc., Faraday Trans.
, 93
(23
), pp. 4159
–4163
.10.
Alxneit
, I.
, and Corboz
, M.
, 1999, “Influence of Photoadsorbed O2 - on the Photoreduction of CO2 With H2O at the Surface of TiO2
,” J. Phys. IV
, 9
(P3
), pp. 295
–299
.11.
Corboz
, M.
, Alxneit
, I.
, Stoll
, G.
, and Tschudi
, H. R.
, 2000, “On the Determination of Quantum Efficiencies in Heterogeneous Photocatalysis
,” J. Phys. Chem. B
, 104
(45
), pp. 10569
–10577
.12.
Linsebigler
, A. L.
, Lu
, G.
, and Yates
, J. T.
, Jr., 1995, “Photocatalysis on TiO2 Surfaces: Principles, Mechanisms, and Selected Results
,” Chem. Rev.
, 95
(3
), pp. 735
–758
.13.
Ulmer
, S.
, Lupfert
, E.
, Pfander
, M.
, and Buck
, R.
, 2004, “Calibration Corrections of Solar Tower Flux Density Measurements
,” Energy
, 29
(5–6
), pp. 925
–933
.14.
Guesdon
, C.
, Alxneit
, I.
, Tschudi
, H. R.
, Wuillemin
, D.
, Petrasch
, J.
, Brunner
, Y.
, Winkel
, L.
, and Sturzenegger
, M.
, 2006, “PSI’s 1 kW Imaging Furnace—A Tool for High-Temperature Chemical Reactivity Studies
,” Sol. Energy
, 80
(10
), pp. 1344
–1348
.15.
Guesdon
, C.
, Alxneit
, I.
, Tschudi
, H. R.
, Wuillemin
, D.
, and Sturzenegger
, M.
, 2006, “1 kW Imaging Furnace With In Situ Measurement of Surface Temperature
,” Rev. Sci. Instrum.
, 77
(3
), 035102
.16.
Weast
, R. C.
, ed., 1989–1990, Handbook of Chemistry and Physics
, 70th ed., CRC Press, Inc.
, Boca Raton
.17.
Smith
, W. J.
, 2008, Modern Optical Engineering
, 4th ed., McGraw-Hill
, NY
.18.
Nakar
, D.
, Malul
, A.
, Feuermann
, D.
, and Gordon
, J. M.
, 2008, “Radiometric Characterization of Ultrahigh Radiance Xenon Short-Arc Discharge Lamps
,” Appl. Opt.
, 47
(2
), pp. 224
–229
.19.
Brandenberg
, W. M.
, 1964, “Focusing Properties of Hemispherical and Ellipsoidal Mirror Reflectometers
,” J. Opt. Soc. Am.
, 54
, p. 1235
.Copyright © 2012
by American Society of Mechanical Engineers
You do not currently have access to this content.