This work proposes and analyses several integration schemes specially conceived for direct steam generation (DSG) in megawatt (MW) range central receiver solar thermal power plants. It is focused on the optical performance related to the heliostat field and the arrangement of receiver absorbers, and the management of steam within a Rankine cycle in the range between 40–160 bar and 400–550 °C at design point. The solar receiver is composed of one single element for saturated steam systems or two vertically aligned separated units, which correspond to the boiler and the superheater (dual-receiver concept), for superheated steam solar thermal power plants. From a fixed heliostat field obtained after layout optimization for the saturated steam solar plant the heliostat field is divided in two concentric circular trapezoids where each of them independently supplies the solar energy required by the boiler and the superheater for the different steam conditions. It has been observed that the arrangement locating the boiler above the superheater provides a slightly higher optical efficiency of the collector system, formed by the solar field and the receiver, compared with the reverse option with superheater above boiler. Besides, two-zone solar fields provide lower performances than the entire heliostat layout aiming at one absorber (saturation systems). Optical efficiency of two-zone solar fields decreases almost linearly with the increment of superheater heat demand. Concerning the whole solar collector, heliostat field plus receiver, the performance decreases with temperature and almost linearly with the steam pressure. For the intervals of steam pressure and temperature under analysis, solar collector of saturated steam plant achieves an optical efficiency 3.2% points higher than the superheated steam system at 40 bar and 400 °C, and the difference increases up to 9.3% points when compared with superheated system at 160 bar and 550 °C. On the other hand, superheated steam systems at 550 °C and pressure between 60 and 80 bar provide the highest overall efficiency, and it is 2.3% points higher than performance of a saturated steam solar plant at 69 bar. However, if saturated steam cycle integrates an intermediate reheat process, both would provide similar performances. Finally, it has been observed that central receiver systems (CRS) producing saturated steam and superheated steam at 500 °C operating at 40 bar provide similar performances.

References

1.
Kolb
,
G. J.
,
Ho
,
C. K.
,
Mancini
,
T. R.
, and
Gary
,
J. A.
,
2011
, “
Power Tower Technology Roadmap and Cost Reduction Plan
,” Sandia National Laboratories, Livermore, CA, Technical Report No. SAND2011-2419.
2.
Romero
,
M.
, and
Gonzalez-Aguilar
,
J.
,
2014
, “
Solar Thermal CSP Technology
,” WIREs Energy Environ., doi: 10.1002/wene.79.
3.
Radosevich
,
L. G.
, and
Skinrood
,
A. C.
,
1989
, “
The Power Production Operation of Solar One, the 10 MWe Solar Thermal Central Receiver Pilot Plant
,”
ASME J. Sol. Energy Eng.
,
111
(
2
), pp.
144
151
.10.1115/1.3268300
4.
Baker
,
A. F.
,
Faas
,
S. E.
, and
Radosevich
,
L. G.
,
1989
, “
U.S.-Spain Joint Evaluation of the Solar One and CESA-1 Receiver and Storage Systems
,” Sandia National Laboratories, Livermore, CA, Technical Report No. SAND88-8262.
5.
Grasse
,
W.
,
Hertlein
,
H. P.
, and
Winter
,
C. J.
,
1991
, “
Thermal Solar Power Plants Experience
,”
Solar Power Plants
,
C. J.
Winter
,
R. L.
Sizmann
, and
L. L.
Vant-Hull
, eds.,
Springer-Verlag
,
Berlin
, pp.
215
282
.
6.
Epstein
,
M.
,
Liebermann
,
D.
,
Rosh
M
, and
Shor
,
A. J.
,
1991
, “
Solar Testing of 2 MWth Water/Steam Receiver at the Weizmann Institute Solar Tower
,”
Sol. Energy Mater.
,
24
, pp.
265
278
.10.1016/0165-1633(91)90067-U
7.
Romero
,
M.
,
González-Aguilar
,
J.
,
2011
, “
Solar Thermal Power Plants: From Endangered Species to Bulk Power Production in Sun-Belt Regions
,”
Energy & Power Generation Handbook
,
K. R.
Rao
, ed.,
ASME
,
New York
, Chap. 3.
8.
Silberstein
,
E.
,
Magen
,
Y.
,
Kroyzer
,
G.
,
Hayut
,
R.
, and
Huss
,
H.
,
2009
, “
Brightsource Solar Tower Pilot in Israel's Negev Operation at 130 Bar and 530 °C Superheated Steam
,”
SolarPACES Conference
, Berlin, Germany, September 15–18, Ed. DLR, Stuttgart, Germany.
9.
Meduri
,
P. K.
,
Hannemann
,
C. R.
, and
Pacheco
,
J. E.
,
2009
, “
Performance Characterization and Operation of eSolar's Sierra Sun Tower Power Plant
,”
SolarPACES Conference
, Berlin, Germany, September 15–18, Ed. DLR, Stuttgart, Germany.
10.
Fernandez-Quero
,
V.
,
Osuna
,
R.
,
Romero
,
M.
,
Sanchez
,
M.
,
Ruiz
,
V.
, and
Silva
,
M.
,
2005
, “
EURECA: Advanced Receiver For Direct Superheated Steam Generation in Solar Towers, as an Option for Increasing Efficiency in Large Low Cost Direct Steam Generation Plants
,”
Proceedings of the Solar World Congress (ISES-2005), Orlando, FL, August 6–12
,
D. Y.
Goswami
,
S.
Vijayaraghaven
, and
R.
Campbell-Howe
, eds.,
American Solar Energy Society
,
Boulder, CO
.
11.
Bobinecz
,
M
.,
2012
, “
BrightSource Ivanpah Solar Electric Generating Facility
,”
44th Engineering and Construction Contracting (ECC) Conference
, San Antonio, TX, September 5–8.
12.
Sanz-Bermejo
,
J.
,
Gonzalez-Aguilar
,
J.
, and
Romero
,
M.
,
2013
, “
Performance Analysis of Direct Steam Generation-Central Receiver Systems
,”
ASME Turbo Expo 2012: Turbine Technical Conference and Exposition
,
Copenhagen, Denmark
, June 11–15,
ASME
Paper No. GT2012-70127, pp.
337
344
.10.1115/GT2012-70127
13.
Ben-Zvi
,
R.
,
Epstein
,
M.
, and
Segal
,
A.
,
2012
, “
Simulation of an Integrated Steam Generator for Solar Tower
,”
Sol. Energy
,
86
(
1
), pp.
578
592
.10.1016/j.solener.2011.11.001
14.
Falcone
,
P. K.
,
1986
, “
A Handbook for Solar Central Receiver Design
,” Sandia National Laboratories, Livermore, CA, Technical Report No. SAND86-8009.
15.
Cotton
,
K. C.
,
1998
,
Evaluating and Improving Steam Turbine Performance
,
Cotton Fact, Inc.
,
Burnt Hills, NY
.
16.
Osuna
,
R.
,
Olavarría
,
R.
,
Morillo
,
R.
,
Sanchez
,
M.
,
Cantero
,
F.
,
Fernandez-Quero
,
V.
,
Robles
,
P.
,
López
,
T.
,
Esteban
,
A.
,
Cerón
,
F.
,
Talegón
,
J.
,
Romero
,
M.
,
Téllez
,
F.
,
Marcos
,
M. J.
,
Martínez
,
D.
,
Valverde
,
A.
,
Monterreal
,
R.
,
Pitz-Paal
,
R.
,
Brakmann
,
G.
,
Ruiz
,
V.
,
Silva
,
M.
, and
Menna
,
P.
,
2006
, “
PS10, Construction of a 11MW Solar Thermal Tower Plant in Seville, Spain
,”
SolarPACES Conference
, Seville, Spain, June 20–23.
17.
Nyqvistm
,
J.
,
Haje
,
D.
, and
Kleinerman
,
K.
,
2010
, “
The Refinement of Industrial Steam Turbines for Efficient Application in Concentrated Solar Power Plants
,”
SolarPACES Conference
, Perpignan, France, September 21–24.
18.
Fernández
,
V.
,
Silva
,
V.
, and
Romero
,
M.
,
2001
, “
WinDelsol 1.0
,”
15th Task III Meeting Within IEA SolarPACES on Solar Technology and Applications
, Cologne, Germany, June 19, SolarPACES Technical Report, DLR, Köln, Germany.
19.
Pawellek
,
R.
,
Low
,
T.
,
Hirsch
,
T.
,
Giuliano
,
S.
, and
Schwarzbözl
,
P.
,
2011
, “
Solar Tower Simulation With EBSILON®Professional
,”
SolarPACES Conference
, Granada, Spain, September 21–24.
20.
Jackson
,
B. W.
,
1996
, “
Steam Generators
,”
Power Plant Engineering
,
L. F.
Drbal
,
P. G.
Boston
,
K. L.
Westr
, and
R. B.
Erickson
, eds.,
Springer
,
New York
.
21.
Becker
,
K. M.
,
Enerholm
,
A.
,
Sardh
,
L.
,
Köhler
,
W.
,
Kastner
,
W.
, and
Krätzer
,
W.
,
1988
, “
Heat Transfer in an Evaporator Tube With Circumferentially Non-Uniform Heating
,”
Int. J. Multiphase Flow
,
14
(
5
), pp.
575
586
.10.1016/0301-9322(88)90059-6
22.
Incropera
,
F. P.
,
DeWitt
,
D. P.
,
Bergman
,
T. L.
, and
Lavine
,
A. S.
,
2006
,
Introduction to Heat Transfer
, 5th ed.,
Wiley
,
New York
, p.
912
.
23.
Kandlikar
,
S. G.
,
1990
, “
A General Correlation for Saturated Two-Phase Flow Boiling Heat Transfer Inside Horizontal and Vertical Tubes
,”
ASME J. Heat Transfer
,
112
, pp.
219
228
.10.1115/1.2910348
24.
Rao
,
K. R.
, ed.,
2009
,
Companion Guide to the ASME Boiler and Pressure Vessel Code
, 3rd ed.,
ASME Press, NY
, pp.
800
.
You do not currently have access to this content.